This Bottom Outlet Stainless Steel Dual Booster Valve manufactured by Joepai is a core inlet assembly for Australian commercial, industrial and residential fire hydrant systems, designed to boost water pressure from fire trucks during emergencies.
All key internal parts adopt grade 304 stainless steel, effectively solving rust and leakage problems of ordinary cast iron boosters, supporting over 10 years stable service life for underground parking lots, seaside projects and high-rise buildings.
The valve arrives pre-assembled with all supporting hardware, paired with a clear installation manual to cut construction time and reduce extra accessory purchasing costs.
Key features
✅ Compliant with AS 2419.3-2012 Australian fire protection standard
Double anti-corrosion protection for harsh environments
Pressure & Dimension Specifications
Nominal pressure: PN14
Working pressure: 1400kPa
Hydraulic test pressure: 2100kPa
Main connection: DN100 roll groove
Fire brigade port: DN65 Storz hose connector
Optional inlet: Queensland round thread
2 mounting versions: compact back mount, vertical bottom mount
Installation Guide
Check all supplied parts: pre-assembled valve body, 2 ball valves, pressure gauge and dust cap sets
Mount the booster valve to pipeline booster points via DN100 roll groove coupling (not provided)
Wrap around 3 layers of thread seal tape on the pressure gauge thread for reliable sealing
Screw the pressure gauge into the top middle isolation ball valve, tighten with spanner and adjust the gauge facing forward for easy reading
Keep drain valve fully open during initial water filling to exhaust internal air; close the drain knob only after all air is fully bled
Open the gauge isolation valve and confirm the pressure gauge displays pipeline data normally
Carry out 1-minute full pressure leakage inspection on all joints and connections
Cover both Storz ports with dust caps linked by chains to finish installation
Important Installation Tips
Thread seal tape wrapping is required to prevent thread joint water leakage
Fully bleed air before closing drain valve to avoid air lock and inaccurate pressure readings
1-minute pressure leakage test is required to meet Australian fire engineering acceptance standards
Core Product Advantages
All 304 stainless steel anti-rust structure
Cast iron boosters easily rust and leak within several years. Our stainless steel structure resists salt fog and long-term outdoor dampness, greatly lowering later maintenance costs.
Pre-assembled all-in-one kit with detailed installation manual
All ball valves, pressure gauge and drain fittings are pre-installed at factory. The operation guide helps fire installers finish assembly faster without sourcing separate spare parts.
Meets Australian fire safety standard for smooth project inspection
Follows AS 2419.3-2012 standard, can pass official fire brigade inspection without secondary modification for contractors and real estate developers.
Compact back and vertical bottom installation options fit different building pipe layouts, suitable for malls, warehouses, apartments and public facilities.
Integrated dual-port compact design
One-piece dual booster housing reduces leakage risks from split pipe joints and saves installation space compared with two separate single boosters.
Application Scenarios
Our Bottom Outlet Stainless Steel Dual Booster Valve is a go-to solution for fire protection projects all across Australia. It works perfectly for high-rise office towers, retail shopping centres, hotels and multi-unit residential apartment buildings. You’ll also find it installed in manufacturing factories, large logistics storage warehouses and chemical processing facilities. Other common sites include underground car parks, medical hospitals, local schools and public sports stadiums. If you’re working on coastal building developments, harbours or marine fire safety setups, this booster valve is built to handle those harsh salt-air conditions too. Fire system tradespeople and businesses offering regular fire hydrant servicing & compliance checks also rely heavily on this model.
FAQ
Q1: Will I receive installation instructions with the booster valve?
A: Absolutely. Every full kit includes a physical printed guide that walks you through the whole process – fitting the valve to pipework, attaching the pressure gauge, purging air from the lines and carrying out leak testing.
Q2: Can this Bottom Outlet Stainless Steel Dual Booster Valve hold up in coastal areas with heavy salt fog?
A: It’s designed exactly for that environment. All key internal parts are made from grade 304 stainless steel, plus the exterior has a fusion bonded anti-corrosion coating, so it resists salt spray damage extremely well for seaside builds.
Q3: Does the package include DN100 roll groove couplings to connect to pipework?
A: The roll groove couplings needed to mount the valve onto your main pipeline are not included in the set; you will need to source these separately on site.
Q4: What mounting configurations are there to suit different pipe layouts?
A: We offer two main fitting styles: compact rear mounting and vertical bottom mounting, which adapt to a wide range of existing building pipe setups.
Q5: What pressure levels can this fire booster valve safely operate at?
A: Its standard working pressure rating sits at 1400kPa, and every unit undergoes factory testing up to 2100kPa, delivering steady reliable performance within high-pressure fire water mains.
JOEPAI focuses on manufacturing stainless steel fire booster valves that meet Australia’s official fire safety standards. We supply these units to fire safety wholesalers, contracting trades and property development teams operating all over the country.We provide bulk wholesale pricing, customized mounting and thread adjustment, fast production lead times and complete standard documents for project tender.
Contact our sales team via email sales@joepaivalve.com or Tel: +86-199-5770-7725 to get dimension drawings, price list and bulk order discounts.
Hot Tags: Bottom Outlet Stainless Steel Dual Booster Valve, Manufacturer, Factory, Made in China
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.Privacy Policy